Module hydraulique Easyflow Logic circuit direct, circuit mélangé, sans régulation
Module hydraulique Easyflow Logic circuit direct, circuit mélangé, sans régulation
Module hydraulique Easyflow Logic circuit direct, circuit mélangé, sans régulation
Module hydraulique Easyflow Logic circuit direct, circuit mélangé, sans régulation
Module hydraulique Easyflow Logic circuit direct, circuit mélangé, sans régulation
Module hydraulique Easyflow Logic circuit direct, circuit mélangé, sans régulation

Easyflow hydraulic module Direct circuit, mixed circuit, unregulated

CHF 821.45
/
Tax included

Select an option to add this to your cart.

Description

Heating operation without domestic hot water production

  • For condensing installations with one mixed and one unmixed heating circuit
  • Optimal use of condensation and energy saving, because the high return temperature from radiators is mixed with the flow from underfloor or wall heating, thus cooling the overall return so that condensation always occurs in the condensing unit
  • Simple mounting thanks to a stable metal base plate
  • Reduced investment and operating costs, as a circulator in the direct circuit is eliminated (the heating unit's circulator is used)
  • Compact and fully pre-assembled
  • Fully pre-wired (in versions with control)

Direct circuit flow

  • 1 × ball valve with red thermometer 0-120°C
  • 1 × differential pressure relief valve

Direct circuit return

  • 1 × ball valve with blue thermometer 0-120°C with liftable gravity check valve

Mixed circuit flow

  • 1 × ball valve with red thermometer 0-120°C
  • 1 × Wilo Para 15/6 SC circulator
  • 1 × bivalent mixer

Mixed circuit return

  • 1 × ball valve with blue thermometer 0-120°C with liftable gravity check valve

Technical Data

Max. operating temperature 95 °C
Max. operating pressure 6 bar
Connections DN25(1") female thread
Gravity check valve 20 mbar
Kvs value direct circuit 5.0
Kvs value mixed circuit 4.0
Max. direct circuit power 35 kW (Δt 20K)
Max. mixed circuit power 12 kW (Δt 8K)
Max. direct circuit flow rate 1510 l/h (Δt 20K)
Max. mixed circuit flow rate 1300 l/h (Δt 8K)
Heat generator center distance 125 mm
Heating circuit center distance 90 mm
Material brass, copper
Insulation EPP
Dimensions (with insulation) HxWxD 516x400x180 mm
For installations with customer-supplied control
Incl. actuator operating voltage 230 V/AC
Max. operating pressure [bar] 6
Version mixed
Depth [mm] 180
Available variants
  • SKU 90 031 99 : Standard
Data sheets
Module hydraulique Easyflow Logic circuit direct, circuit mélangé, sans régulation
Standard 90 031 99
CHF 821.45 /each
Total: